• NEO MonitorsÀÇ LaserGas™ III Ultra SP COG H2S´Â º¹ÀâÇÑ COG »ùÇà ½ºÆ®¸²°ú ±ä °æ·Î ±æÀÌ¿¡¼ °í°¨µµ°¡ ¿ä±¸µÇ´Â °í¼º´É H2S ÃøÁ¤À» À§ÇØ Æ¯º°È÷ ¼³°èµÈ Çõ½ÅÀûÀÎ TDLAS ±â¼úÀ» »ç¿ëÇÑ ºÐ¼®±âÀÔ´Ï´Ù. º£À̽º¶óÀο¡ ¹Î°¨ÇÏÁö ¾Ê°í NEO Monitors ¸¸ÀÇ Æ¯Çã±â¼úÀÎ IROSS™ ½Ã±×³Î ÇÁ·Î¼¼½Ì ¾Ë°í¸®ÁòÀ» »ç¿ëÇÏ¿©, ±î´Ù·Î¿î ¾îÇø®ÄÉÀ̼ǿ¡¼µµ ¹®Á¦¾øÀÌ ÃøÁ¤ °¡´ÉÇÕ´Ï´Ù. LaserGas™ III Ultra SP COG H2S´Â ÀÌ·¯ÇÑ ±î´Ù·Î¿î Á¶°Ç¿¡¼µµ ½Å·ÚÇÒ ¼ö ÀÖ´Â ¿Ïº®ÇÑ ºÐ¼®±âÀÔ´Ï´Ù. ÁÖ¿ä Æ¯Â¡
• In-situ ½Ç½Ã°£ ÃøÁ¤ • Laser TDLAS ±â¼ú
• Æø³ÐÀº ÃøÁ¤ ¹üÀ§
• IROSS™ ½Ã±×³Î ÇÁ·Î¼¼½Ì
• ³·Àº detection limit
• ÃøÁ¤ ½Ã Ÿ °¡½º °£¼· ¾øÀ½
• ¸¹Àº ¸ÕÁö·®¿¡µµ Àû¿ë °¡´É
• ¾ÈÁ¤ÀûÀÎ Calibration
• Zero drift ¾øÀ½
• Span check ÀÏüÈ
• ÄÄÆÑÆ®ÇÑ µðÀÚÀÎ
• 10W ÀÌÇÏ ³·Àº Àü·Â ¼Òºñ
• Ethernet ¿¬°á °¡´É
Àû¿ë »ç·Ê
• Coke Oven Gas (COG)
• Á¤Á¦ °øÀå
• ¹ßÀü¼Ò
• ÈÇÐ »ê¾÷
• ¼®À¯ÈÇÐ »ê¾÷
• Á¦Ã¶ ¹× ö° »ê¾÷
• ±× ¿Ü ´Ù¼ö
ÁÖ¿ä ÀåÁ¡
• ´ÜÀÏ ºÐ¼®±â·Î ÇÁ·Î¼¼½º Á¦¾î¿Í ¾ÈÀü°ü¸® µ¿½Ã ÁøÇà
• ½Å·Úµµ ³ôÀº ½Ç½Ã°£ in-situ H2S ÃøÁ¤
• ±ä ÃøÁ¤ °æ·Î ¹× Æø³ÐÀº ÃøÁ¤ ¹üÀ§
• ¿¬·á ¼Òºñ·® °¨¼Ò
• °£´ÜÇÑ ¼³Ä¡ ¹× ¼Õ½¬¿î »ç¿ë¹ý
• ³·Àº À¯Áöº¸¼ö ºñ¿ë
• ¼Ò¸ðǰ ¾øÀ½
• »ùÇøµ ½Ã½ºÅÛ ºÒÇÊ¿ä
• ¾ÐÃà ¿¡¾î ÆÛÁö °¡´É(N2 ºÒÇÊ¿ä)
• ¿¬ 1ȸ ±³Á¤ Ãßõ
• º¹ÇÕ °¡½º
• SPECIFICATIONS
- Detection limit(LDL): 5ppm - Process gas temperature: min. 20°C/ max. 70°C - Process gas pressure: min. 0.9barA / max. 1.3barA
- Optical path length: Typically 0.5 - 30m - Repeatability: 0.2ppm
- Linearity: <1% of range
- Response time: < 5 seconds • ENVIRONMENTAL CONDITIONS
- Operating temperature: -40 °C - +65 °C - Storage temperature: -40 °C to +70 °C - Protection classification: IP65 • INPUT / OUTPUT
- Analog output(3): 4 - 20 mA current loop(concentraion and transmission) - Digital output: 10/100 Base T Ethernet (Modbus/TCP)
- Relay output(2): High gas, warning and fault (normally closed) - Analog input: 4 - 20 mA process temperature and pressure reading • RATINGS
- Power supply: 24 VDC, range 18 - 32 VDC - Power consumptions: max 20W - 4 - 20 mA output: 500 Ohm max. load impedance, not isolated - Relay output: 1 A at 30 V DC • SAFETY
- Laser class: Class 1M according to IEC 60825-1, eye safe - CE: Certified - EMC: Conformant with directive 2014/30/EU • APPROVALS
- ATEX zone 1: Ex db [op is Ga] IIC T4 Gb, Ex tb [op is Da] IIIC T100°C Db - CSA: Class I Div.2, Groups B, C and D, T4 - ATEX rating connetion box: II 2 GD Ex e IIC T5, II 2 D Ex e tb IIIC T85°C Db • INSTALLATION AND OPERATION
- Flange dimension: DN50/PN10 or ANSI 2"/150lbs (other dimensions on request) - Alitnment tolerances: Flanges parallel within 1.5°
- Purge of windows: Dry and oil-free pressurised air or gas, or by fan - Purge flow: 10-50l/min (application dependent) • MAINTENANCE
- Calibration: Check recommended every 12 months - Validation: In-situ span check with optional internal cell (application dependent) • DIMENSIONS / WEIGHT
- Transmitter and receiver unit(TU/RU): 215mm(length, add 50mm for purge unit) x 125mm(diameter), 3.5kg each - TU/RU connection box: 260mm x 160mm x 90mm, 2.5kg
♦ LaserGas™ III Ultra SP COG H2S
♦ Typical process conditions
** NOTE: LDL is defined as the maximum peak-to-peak value of a 24 hour temperature cycle test(-40°C to +65°C) using 1s update time. LDL also includes typical background inerferences not explicitly defined in the table.
|
![]() |